Instructions on how to clean the liquid cooling ring on an FMB Group dry cleaning machines...
How to clean the Liquid Cooling Ring Tank:
-
Press button on/lock off
2. Press button #20 (still heat) off
3. Press button Man./Pause on
4. Open red butterfly drain valve located on bottom left of liquid ring cooling tank
5. Press buttons #25 (still inlet) and #28 (pump) on for 15 seconds or until liquid ring cooling tank drains completely to the still
6. Close red butterfly drain valve
7. Press buttons #25, #28, and Man./Pause off
8. Remove sight glass on liquid ring cooling tank and clean inside the tank with the recommended anti-bacterial cleaner and wipe dry
9. Clean the sight glass
10. Clean the float sensor inside the liquid ring cooling tank
11. Replace the sight glass and change the gasket if necessary & tighten nuts
12. Press buttons Man./Pause, #50, #25, and #28 on for 25 seconds
13. Press buttons #28, #25, and #50 off
14. Press buttons #14 (outlet of tank 3), #24 (inlet of tank 3), and #28 (pump) on
15. Open yellow handle ball valve above the liquid ring cooling tank to fill with solvent. Note: if solvent flow is slow you may press button #24 off
16. Fill liquid ring cooling tank with solvent to the MAX line
17. Close the yellow handle ball valve
18. Press buttons #28, #24, #14, and Man./Pause off
19. Press button #20 on
20. Check for leaks.